Categories
B Braun L6100 – 5% Dextrose and 0.9% Sodium Chloride Injection USP, 1000 mL, 12/CS
B Braun L6100 Dextrose and Sodium Chloride Injections USP
Dextrose and Sodium Chloride Injections USP are sterile, nonpyrogenic and contain no bacteriostatic or antimicrobial agents. These products are intended for intravenous administration. These intravenous solutions are indicated for use in adults and pediatric patients as sources of electrolytes, calories and water for hydration.
Not made with natural rubber latex, PVC or DEHP.
Clinical Pharmacology of B Braun L6100
Dextrose and Sodium Chloride Injections USP provide electrolytes and calories and are a source of water for hydration. All are capable of inducing diuresis depending on the clinical condition of the patient.
Sodium, the major cation of the extracellular fluid, functions primarily in the control of water distribution, fluid balance, and osmotic pressure of body fluids. Sodium is also associated with chloride and bicarbonate in the regulation of the acid-base equilibrium of body fluid.
Chloride, the major extracellular anion, closely follows the metabolism of sodium, and changes in the acid-base balance of the body are reflected by changes in the chloride concentration.
Dextrose provides a source of calories. Dextrose is readily metabolized, may decrease losses of body protein and nitrogen, promotes glycogen deposition and decreases or prevents ketosis if sufficient doses are provided.
B Braun L6100 Dextrose and Sodium Chloride Injections USP Indications and Usage
These intravenous solutions are indicated for use in adults and pediatric patients as sources of electrolytes, calories and water for hydration.
B Braun L6100 Contraindications
These solutions are contraindicated where the administration of sodium or chloride could be clinically detrimental. Solutions containing dextrose may be contraindicated in patients with hypersensitivity to corn products.
B Braun L6100 Directions for Use of Excel Container
To Open
Tear overwrap down at notch and remove solution container. Check for minute leaks by squeezing solution container firmly. If leaks are found, discard solution as sterility may be impaired. If supplemental medication is desired, follow directions below before preparing for administration.
NOTE: Before use, perform the following checks:
Inspect each container. Read the label. Ensure solution is the one ordered and is within the expiration date.
Invert container and carefully inspect the solution in good light for cloudiness, haze, or particulate matter. Any container which is suspect should not be used.
Use only if solution is clear and container and seals are intact.
Preparation for Administration
- Remove plastic protector from sterile set port at bottom of container.
- Attach administration set. Refer to complete directions accompanying set.
To Add Medication
Warning: Some additives may be incompatible.
To Add Medication Before Solution Administration
- Prepare medication site.
- Using syringe with 18 22 Ga. needle, puncture medication port and inner diaphragm and inject.
- Squeeze and tap ports while ports are upright and mix solution and medication thoroughly.
To Add Medication During Solution Administration
- Close clamp on the set.
- Prepare medication site.
- Using syringe with 18 22 Ga. needle of appropriate length (at least 5/8 inch), puncture resealable medication port and inner diaphragm and inject.
- Remove container from IV pole and/or turn to an upright position.
- Evacuate both ports by tapping and squeezing them while container is in the upright position.
- Mix solution and medication thoroughly.
- Return container to in use position and continue administration.
B Braun L6100 Product Specifications
Product Code | L6100 |
NDC NUMBER | 7610 |
NDC Number | 00264-7610-00 |
Reference Number | L6100 |