Categories
Baxter 2B0087 – 5% Dextrose Injection, USP, 100 mL VIAFLEX Plastic Container, 96/CS
Baxter 2B0087 Dextrose Injection, USP in VIAFLEX Plastic Container
Dextrose Injection, USP is a sterile, nonpyrogenic solution for fluid replenishment and caloric supply in single dose containers for intravenous administration. It contains no antimicrobial agents. Composition, osmolarity, pH, and caloric content are shown in Table 1.
The VIAFLEX plastic container is fabricated from a specially formulated polyvinyl chloride (PL 146 Plastic). The amount of water that can permeate from inside the container into the overwrap is insufficient to affect the solution significantly. Solutions in contact with the plastic container can leach out certain of its chemical components in very small amounts within the expiration period, e.g., di-2-ethylhexyl phthalate (DEHP), up to 5 parts per million. However, the safety of the plastic has been confirmed in tests in animals according to USP biological test for plastic containers as well as by tissue culture toxicity studies.
Baxter 2B0087 Clinical Pharmacology
Dextrose Injection, USP has value as a source of water and calories. It is capable of inducing diuresis depending on the clinical condition of the patient.
Indications and Usage of Baxter 2B0087
Dextrose Injection, USP is indicated as a source of water and calories.
Baxter 2B0087 Contraindications
Solutions containing dextrose may be contraindicated in patients with known allergy to corn or corn products.
Directions for Use of VIAFLEX Plastic Container
To Open
Tear overwrap down side at slit and remove solution container. Visually inspect the container. If the outlet port protector is damaged, detached, or not present, discard container as solution path sterility may be impaired. Some opacity of the plastic due to moisture absorption during the sterilization process may be observed. This is normal and does not affect the solution quality or safety. The opacity will diminish gradually. Check for minute leaks by squeezing inner bag firmly. If leaks are found, discard solution as sterility may be impaired. If supplemental medication is desired, follow To Add Medication directions below.
Preparation for Administration
- Suspend container from eyelet support.
- Remove protector from outlet port at bottom of container.
- Attach administration set. Refer to complete directions accompanying set.
To Add Medication
Additives may be incompatible.
To add medication before solution administration
- Prepare medication site.
- Using syringe with 19 to 22 gauge needle, puncture resealable medication port and inject.
- Mix solution and medication thoroughly. For high density medication such as potassium chloride, squeeze ports while ports are upright and mix thoroughly.
To add medication during solution administration
- Close clamp on the set.
- Prepare medication site.
- Using syringe with 19 to 22 gauge needle, puncture resealable medication port and inject.
- Remove container from IV pole and/or turn to an upright position.
- Evacuate both ports by squeezing them while container is in the upright position.
- Mix solution and medication thoroughly.
- Return container to in-use position and continue administration.